Effects of argon gas flow rate on laser-welding

この論文にアクセスする

この論文をさがす

著者

    • TAKAYAMA Yasuko
    • Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine
    • NOMOTO Rie
    • Department of Dental Engineering, Tsurumi University School of Dental Medicine
    • OHKUBO Chikahiro
    • Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine

抄録

The purpose of this study was to evaluate the effects of the rate of argon gas flow on joint strength in the laser-welding of cast metal plates and to measure the porosity. Two cast plates (Ti and Co-Cr alloy) of the same metal were abutted and welded together. The rates of argon gas flow were 0, 5 and 10 L/min for the Co-Cr alloy, and 5 and 10 L/min for the Ti. There was a significant difference in the ratio of porosity according to the rate of argon gas flow in the welded area. Argon shielding had no significant effect on the tensile strength of Co-Cr alloy. The 5 L/min specimens showed greater tensile strength than the 10 L/min specimens for Ti. Laser welding of the Co-Cr alloy was influenced very little by argon shielding. When the rate of argon gas flow was high, joint strength decreased for Ti.

収録刊行物

  • Dental materials journal

    Dental materials journal 31(2), 316-326, 2012-03-01

    日本歯科理工学会