Dopamine Detection on Boron-doped Diamond Electrodes Using Fast Cyclic Voltammetry

この論文にアクセスする

この論文をさがす

著者

    • KATO Taisuke
    • Department of Chemistry, Faculty of Science and Technology, Keio University
    • FIERRO Stephane
    • Department of Chemistry, Faculty of Science and Technology, Keio University
    • WATANABE Takeshi
    • Department of Chemistry, Faculty of Science and Technology, Keio University
    • YOSHIMI Kenji
    • Department of Neurophysiology, School of Medicine, Juntendo University
    • EINAGA Yasuaki
    • Department of Chemistry, Faculty of Science and Technology, Keio University

抄録

A new method is proposed for the accurate and reproducible detection of dopamine using cyclic voltammetry on boron-doped diamond (BDD) electrode. It is shown that reproducible voltammograms can be obtained when applying a relatively high scan rate (100 V s<sup>−1</sup>) during the detection measurements. For lower scan rates (1 V s<sup>−1</sup>), it is proven that electrode fouling occurs due do the deposition of a polymer at the electrode surface arising from the oxidation of aminochrome. Cyclic voltammetry measurements of the [Fe(CN)<sub>6</sub>]<sup>3−</sup>/[Fe(CN)<sub>6</sub>]<sup>4−</sup> couple performed before and after dopamine detection on BDD and glassy carbon electrodes have shown that the electrochemical activity of the electrode decreases only at low scan rates for BDD dopamine (DA) detection, which leads to electrode poisoning whereas the activity remains unchanged for higher scan rates. However, on glassy carbon electrodes, the electrochemical activity of the material decreases after DA detection measurements independently of the scan rate applied. Therefore, this study shows that electrode fouling during the detection of dopamine by cyclic voltammetry can be avoided only when using BDD electrode but also only for high applied scan rates.

収録刊行物

  • Chemistry letters

    Chemistry letters 41(3), 224-226, 2012-03-05

    公益社団法人 日本化学会

参考文献:  13件中 1-13件 を表示

  • <no title>

    TU Y.-F.

    Biosens. Bioelectron. 17, 19, 2002

    被引用文献1件

  • <no title>

    HUANG J.

    Biosens. Bioelectron. 24, 632, 2008

    被引用文献1件

  • <no title>

    POPA E.

    Electrochem. Solid-State Lett. 2, 49, 1999

    被引用文献1件

  • <no title>

    KONDO T.

    Electrochim. Acta 54, 2312, 2009

    被引用文献1件

  • <no title>

    WEI M.

    Adv. Funct. Mater. 18, 1414, 2008

    被引用文献1件

  • <no title>

    BARD A. J.

    Electrochemical Methods : Fundamentals and Applications, 1980

    被引用文献1件

  • <no title>

    MAJEWSKA U. E.

    Electroanalysis 18, 1463, 2006

    被引用文献1件

  • <no title>

    FUJISHIMA A. ed.

    Diamond Electrochemistry, 2005

    被引用文献1件

  • <no title>

    LUCZAK T.

    Electrochim. Acta 53, 5725, 2008

    被引用文献1件

  • <no title>

    CHIKU M.

    J. Electroanal. Chem. 612, 201, 2008

    被引用文献1件

  • <no title>

    CISZEWSKI A.

    Anal. Chem. 71, 1055, 1999

    被引用文献5件

  • <no title>

    SUZUKI A.

    Anal. Chem. 79, 8608, 2007

    被引用文献3件

  • <no title>

    YANO T.

    J. Electrochem. Soc. 145, 1870, 1998

    DOI 被引用文献10件

各種コード

  • NII論文ID(NAID)
    10030223874
  • NII書誌ID(NCID)
    AA00603318
  • 本文言語コード
    ENG
  • 資料種別
    SHO
  • ISSN
    03667022
  • データ提供元
    CJP書誌  J-STAGE 
ページトップへ