The development of whole rock analysis of major and trace elements in XRF glass beads by fsLA-ICPMS in GSJ geochemical reference samples

この論文にアクセスする

この論文をさがす

著者

抄録

Using laser-ablation inductively coupled plasma mass spectrometer (LA-ICPMS), we have improved the reliability of the abundance data for trace-elements in geochemical samples using a glass bead ablation method. The glass beads were made of mixture of 0.1 g sample and 1.0 g of lithium-tetraborate preliminary prepared for an analysis of major components using a X-ray fluorescence (XRF) technique. The present method has several advantages: 1) higher sensitivity than that achieved by the XRF method, 2) obviation of erroneous measurements due to incomplete dissolution of heavy minerals, and 3) simple, rapid and user friendly sample preparation procedures for the analysis of both the major and trace elements. Development of this method constitute: 1) femtosecond laser-ablation for minimal elemental fractionation during the laser ablation, 2) new software to control all the laser, sample stage movement as well as triggering the data acquisition using the ICP-MS, and 3) a newly designed sample cell to enhance the transport efficiency of the sample aerosol into the ICP. Moreover, to improve the data quality for both the major and trace elements, calibration lines were defined based on the Li-normalized signal intensities and the reported abundance values for the analytes in well distributed GSJ geochemical reference samples. These improvements enabled us to analyze whole-rock compositions at ≤100 sec/sample. Using this method, the precisions of analyses were better than 10% for Na, Mg, Al, Si, K, Ca, Sc, Ti, V, Mn, Co, Ga, Rb, Sr, Y, Zr, Nb, La, Pr and Nd; 20% for P, Zn, Sn, Ce, Sm, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, Th, and U, and 30% for Fe, Cs, Ba, and Eu. For Ni and As, precisions of the measurements was not better than 30%. Reliabilities of analyses were better than 10% for Na, Mg, Al, Si, K, Ca, Sc, Ti, V, Mn, Co, Rb, Sr, Y, Zr, Cs, Ba, La, Ce, Nd, Sm, Gd, Tb, Dy, Yb, Lu, Hf, Th and U; <20% for Zn, Ga, Nb, Sn, Pr, Sm, Eu, Ho, Er, Tm and Ta, and 30% for P. For Fe, Ni and As, reliability of the measurement was not better than 30%.

収録刊行物

  • Geochemical journal : journal of the Geochemical Society of Japan

    Geochemical journal : journal of the Geochemical Society of Japan 45(5), 387-416, 2011-10-01

    一般社団法人日本地球化学会

参考文献:  27件中 1-27件 を表示

被引用文献:  1件中 1-1件 を表示

各種コード

  • NII論文ID(NAID)
    10030363064
  • NII書誌ID(NCID)
    AA00654975
  • 本文言語コード
    ENG
  • 資料種別
    ART
  • ISSN
    00167002
  • NDL 記事登録ID
    11288018
  • NDL 雑誌分類
    ZM41(科学技術--地球科学)
  • NDL 請求記号
    Z53-R488
  • データ提供元
    CJP書誌  CJP引用  NDL  J-STAGE 
ページトップへ