座位両足開閉ステッピングテストの考案と作成 : 測定値の信頼性について Development of a 10-second Open-Close Stepping Test Reliability of Measurement Value

この論文にアクセスする

この論文をさがす

著者

    • 小林 薫 KOBAYASHI KAORU
    • 国際医療福祉大学 保健医療学部理学療法学科 Department of Physical Therapy, Faculty of Health Science, International University of Health and Welfare
    • 丸山 仁司 MARUYAMA HITOSHI
    • 国際医療福祉大学 保健医療学部理学療法学科 Department of Physical Therapy, Faculty of Health Science, International University of Health and Welfare
    • 柊 幸伸 HIIRAGI YUKINOBU
    • 国際医療福祉大学 小田原保健医療学部理学療法学科 Department of Physical Therapy, Faculty of Health Science at Odawara, International University of Health and Welfare

抄録

〔目的〕我々は,「座位両足開閉ステッピングテスト」を考案し,測定時間の決定および測定値の信頼性について検討した.〔対象〕測定時間の決定(研究Ⅰ)は,若年者48名(男性24名,女性24名)を対象とした.検者内・検者間信頼性(研究Ⅱ)は,検者A,Bの2名とし,対象は若年者10名(男性4名,女性6名)とした.〔方法〕研究Ⅰは,測定時間5,10,15,20秒間とし,1回ずつ測定したのち,同様の手順で再度測定を実施した.研究Ⅱは,測定時間を10秒間とし,検者A,Bともに2回ずつ測定した.〔結果〕研究Ⅰの級内相関係数(ICC)(1.1)は,5,10,15,20秒間の順に0.66,0.78,0.78,0.71であった.研究ⅡのICC(1.1)は,検者A,Bでそれぞれ0.90,0.92であり,ICC(2.1)(3.1)はともに0.96であった.検者内・検者間ともに系統誤差は認められなかった.〔結語〕測定時間を10秒間とすると,検者内・検者間信頼性がよく,安定した測定値が得られることが明らかとなった.

[Purpose] We have developed the 10-second Open-Close Stepping Test (OCS-10), was examined reliability of the measurement values and determination of the measurement time. [Subjects] Determination of the measurement time (Study 1), the subjects were 48 young people (24 males and 24 females), and for the intra-rater and the inter-rater reliability (Study 2), there were two examiners, A and B, and the subjects were 10 young people (4 males and 6 females). [Method] In study 1, measurement time was set to 5, 10, 15, 20 seconds. Then repeated the measurements in the same order. In study 2, examiners A and B made two times with a measurement time was 10 seconds. [Results] In study 1, the intraclass correlation coefficient (ICC) (1.1) was examiners A and B were 0.90 and 0.92, respectively. ICC (2.1) and ICC (3.1) were both 0.96. The intra-rater and the inter-rater systematic errors were not found. [Conclusion] The results show that at a measurement time of 10 seconds, the intra-rater and the inter-rater reliability was good and stable measurement values could be obtained.

収録刊行物

  • 理学療法科学

    理学療法科学 27(2), 109-114, 2012-04-20

    理学療法科学学会

参考文献:  21件中 1-21件 を表示

各種コード

  • NII論文ID(NAID)
    10030767061
  • NII書誌ID(NCID)
    AN10472896
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    13411667
  • NDL 記事登録ID
    023781968
  • NDL 請求記号
    Z7-1893
  • データ提供元
    CJP書誌  NDL  IR  J-STAGE 
ページトップへ