非接触給電装置の共振回路高効率化のための受電側降圧コンバータの動作条件の検討

書誌事項

タイトル別名
  • Consideration of Operating Condition of Secondary-side Converter of Inductive Power Transfer System for Obtaining High Resonant Circuit Efficiency
  • ヒセッショク キュウデン ソウチ ノ キョウシン カイロ コウコウリツカ ノ タメ ノ ジュデンガワコウアツ コンバータ ノ ドウサ ジョウケン ノ ケントウ

この論文をさがす

抄録

Contactless power transfer (CPT) system is of interest because of its potential for use in electric vehicle chargers. The system can make convenient to charge the battery on electric vehicles even on a rainy day. However, there are some barriers that should be overcome for the practical realization of the CPT system. These include parameter variation associated with the parking position at a parking lot and the low system efficiency. Several CPT schemes have been proposed and researched. This paper reviews inductive CPT system in these schemes. First, a theoretical formula suitable for treating two kinds of parameter variations associated with the caused by coupling state between the primary and secondary coils or parking position is derived. Next, a maximum efficiency operation scheme is proposed on the basis of the formula and theoretical analysis. Experimental results show the effectiveness of the proposed operation scheme.

収録刊行物

被引用文献 (12)*注記

もっと見る

参考文献 (19)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ