Corrosive effect of disinfection solution containing hydroxyl radicals generated by photolysis of H<sub>2</sub>O<sub>2</sub> on dental metals

  • NAKAMURA Keisuke
    Laboratory for Redox Regulation, Tohoku University Graduate School of Dentistry
  • YAMADA Yasutomo
    Division of Fixed Prosthodontics, Tohoku University Graduate School of Dentistry
  • TAKADA Yukyo
    Division of Dental Biomaterials, Tohoku University Graduate School of Dentistry
  • MOKUDAI Takayuki
    Laboratory for Redox Regulation, Tohoku University Graduate School of Dentistry
  • IKAI Hiroyo
    Division of Fixed Prosthodontics, Tohoku University Graduate School of Dentistry
  • INAGAKI Ryoichi
    Division of Fixed Prosthodontics, Tohoku University Graduate School of Dentistry
  • KANNO Taro
    Division of Fixed Prosthodontics, Tohoku University Graduate School of Dentistry
  • SASAKI Keiichi
    Division of Fixed Prosthodontics, Tohoku University Graduate School of Dentistry
  • KOHNO Masahiro
    Department of Bioengineering, Graduate School of Bioscience and Biotechnology, Tokyo Institute of Technology
  • NIWANO Yoshimi
    Laboratory for Redox Regulation, Tohoku University Graduate School of Dentistry

Bibliographic Information

Other Title
  • Corrosive effect of disinfection solution containing hydroxyl radicals generated by photolysis of H2O2 on dental metals

Search this article

Abstract

The purpose of the present study was to evaluate the corrosive effect of disinfection solution containing hydroxyl radicals generated by photolysis of H2O2on dental metals. Static immersion test was performed on four different dental metals: Ti, Type 316L stainless steel, Ag-Pd-Cu-Au alloy, and Co-Cr alloy. Metal specimens were immersed in 1 M H2O2(=3.4%) with or without light-emitting diode (LED) light irradiation (wavelength: 400 nm) for 1 week, and then the amounts of released ions were analyzed. Corrosive effect of the disinfection solution containing hydroxyl radicals on any dental metals tested in the present study never exceeded that of H2O2 alone. Therefore, disinfection systems based on the photolysis of H2O2 for the cleaning of dentures and treatment of oral infectious diseases would not cause problematic metal corrosion whenever the concentration of H2O2 does not exceed 3%, which is a concentration used as an oral disinfectant.

Journal

  • Dental Materials Journal

    Dental Materials Journal 31 (6), 941-946, 2012

    The Japanese Society for Dental Materials and Devices

Citations (2)*help

See more

References(50)*help

See more

Related Projects

See more

Details 詳細情報について

Report a problem