骨シンチグラフィ全身プラナー像におけるTop-hat変換処理の有用性に関する検討

書誌事項

タイトル別名
  • Usefulness of Top-hat Transform Processing in Whole Body Bone Scintigraphy
  • ホネ シンチグラフィ ゼンシン プラナーゾウ ニ オケル Top-hat ヘンカン ショリ ノ ユウヨウセイ ニ カンスル ケントウ

この論文をさがす

抄録

To assess the usefulness of top-hat transform processing in whole body bone scintigraphy, five radiological technicians interpreted both original and top-hat processed images to determine the improvement of lesion detectability and interpretation time. For the evaluation of detectability, receiver operating characteristic (ROC) analysis was performed. The area under the curve (AUC) calculated from the ROC curve was improved in all observers (from 0.786 to 0.864 in average), although no significant difference was observed. However, the interpretation time was improved significantly (from 24.5 to 16.2 s in average). Top-hat transform processing in whole body bone scintigraphy is thought to be useful for the improvement of lesion detectability and interpretation time.

収録刊行物

参考文献 (25)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘