Imaging of M^|^eacute;ni^|^egrave;re's Disease by Subtraction of MR Cisternography from Positive Perilymph Image

  • NAGANAWA Shinji
    Department of Radiology, Nagoya University Graduate School of Medicine
  • YAMAZAKI Masahiro
    Department of Radiology, Nagoya University Graduate School of Medicine
  • KAWAI Hisashi
    Department of Radiology, Nagoya University Graduate School of Medicine
  • BOKURA Kiminori
    Department of Radiology, Nagoya University Graduate School of Medicine
  • SONE Michihiko
    Department of Otorhinolaryngology, Nagoya University Graduate School of Medicine
  • NAKASHIMA Tsutomu
    Department of Otorhinolaryngology, Nagoya University Graduate School of Medicine

書誌事項

タイトル別名
  • Imaging of Ménière's Disease by Subtraction of MR Cisternography from Positive Perilymph Image

この論文をさがす

抄録

To visualize endolymph, perilymph, and bone separately in a single image after intravenous injection of single-dose gadodiamide, we generated a HYDROPS2 image (subtraction of MR cisternography from heavily T2-weighted 3-dimensional fluid-attenuated inversion recovery image) in 12 patients with suspected Ménière's disease. The contrast-to-noise ratio of endo- and perilymph did not differ significantly between the HYDROPS2 and previously reported HYDROPS (hybrid of reversed image of positive endolymph signal and native image of positive perilymph Signal) images, and scan time was 40% shorter for the HYDROPS2 than HYDROPS.<br>

収録刊行物

被引用文献 (12)*注記

もっと見る

参考文献 (26)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ