書誌事項
- タイトル別名
-
- Effects of Intermediate-frequency Magnetic Fields on Isolated Perfused Rat Small Arteries
- チュウカンシュウハ ジカイ バクロ ニ ヨル ラット ショウドウミャク ケッカンケイ エ ノ エイキョウ ヒョウカ
この論文をさがす
抄録
As induction heating (IH) equipments are getting widely used, the intermediate-frequency magnetic fields emitted by these equipments have been attracting much attention especially from health and safety viewpoints. However, studies on microcirculation are scarce. Here, we aimed at evaluating possible effects of the magnetic field (24 kHz) emitted by an IH on isolated perfused small arteries. Mesenteric arteries (346 ± 30 μm) of Wistar rats (n = 12 for both exposure and control groups) were isolated and perfused with a vessel perfusion system (0.02 mL/min, 90 mmHg). A table-top type IH was located 250 mm apart from a vessel. Each vessel was then exposed to a magnetic field of 7.8 μT for 10 min. Inner and outer diameters were measured during and after exposure. Insignificant decreasing trends (< 1%) of vessel diameters were noticed; however, no statistically significant changes were observed compared with the control group.
収録刊行物
-
- 生体医工学
-
生体医工学 47 (6), 508-513, 2009
公益社団法人 日本生体医工学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282680243086080
-
- NII論文ID
- 10031199713
-
- NII書誌ID
- AA11633569
-
- ISSN
- 18814379
- 1347443X
-
- NDL書誌ID
- 10594640
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- CiNii Articles
- KAKEN
-
- 抄録ライセンスフラグ
- 使用不可