Research on the Vibration Analysis of Intracranial Pressure Pulse Wave. Computer Simulation for Intracranial Pressure Pulse Wave based on Linear Vibration Model.

Bibliographic Information

Other Title
  • 頭蓋内圧脈波の振動解析に関する研究  線形振動モデルによるシミュレーション
  • ズガイ ナイアツ ミャクハ ノ シンドウ カイセキ ニ カンスル ケンキュウ センケイ シンドウ モデル ニ ヨル シミュレーション
  • Computer Simulation for Intracranial Pressure Pulse Wave based on Linear Vibration Model
  • 線形振動モデルによるシミュレーション

Search this article

Abstract

To understand the relation between arterial pressure (AP) waves and intracranial pressure (ICP) pulse waves, animal experiments using cats and computer simulation based on linear vibration model are carried out. In animal experiments, acute brain compression by epidural balloon inflation is performed. By increasing of ICP at the beginning of experiments, the equivalent compliance estimated by computer simulation decreases to low value. Although ICP returns to low by balloon deflation, the equivalent compliance remains low. These results suggest that the compliance estimated by the computer simulation is available for the indicator of pathological changes in intracranial functions.