曲線推進工法における点光源を利用した位置検出装置の開発  [in Japanese] Position Sensing System Using Point Source of Light for Curved Micro-tunneling  [in Japanese]

Access this Article

Search this Article

Author(s)

Abstract

Curved micro-tunneling using small conduit pipes with diameters of 1m or less is recently applied in many construction sites. A new position sensing system to pinpoint the head of the first pipe has been come up with even when it cannot be seen directly from the base position. It differs from the traditional method of using the collimated laser beam, in that the diode laser with a large divergence is used as a point source of light and the direction of the point source of light is detected by using an objective lens and CCD camera. To apply this method to the position detection of the first pipe, the structure of the sensing unit and its detection accuracy were examined and the following results were obtained. (1) The structure using polarized beam splitter can suppress error led by rotating the sensing unit. (2) Through the simulation and some field tests, 20 seconds or less detection accuracy of direction angle was achieved.

Journal

  • Journal of the Japan Society for Precision Engineering

    Journal of the Japan Society for Precision Engineering 66(5), 786-790, 2000-05-05

    The Japan Society for Precision Engineering

References:  3

Codes

  • NII Article ID (NAID)
    110001368112
  • NII NACSIS-CAT ID (NCID)
    AN1003250X
  • Text Lang
    JPN
  • Article Type
    ART
  • ISSN
    09120289
  • NDL Article ID
    5366059
  • NDL Source Classification
    ZN12(科学技術--機械工学・工業--精密機械)
  • NDL Call No.
    Z16-466
  • Data Source
    CJP  NDL  NII-ELS  J-STAGE 
Page Top