種々の埋没材を用いて歯科精密鋳造した生体用Ti-29Nb-13Ta-4.6Zr合金の引張特性と鋳造欠陥との関係

書誌事項

タイトル別名
  • Relationship between Tensile Properties and Casting Defect of Ti-29Nb-13Ta-4.6Zr for Biomedical Applications Cast by Dental Precision Casting Process Using Various Investment Materials
  • シュジュ ノ マイボツザイ オ モチイテ シカ セイミツ チュウゾウ シタ セイタイヨウ Ti 29Nb 13Ta 4 6Zr ゴウキン ノ ヒッパリ トクセイ ト チュウゾウ ケッカン ト ノ カンケイ

この論文をさがす

抄録

Relationship between tensile properties and casting defect of newly developed β type titanium alloy, Ti-29Nb-13Ta-4.6Zr, for biomedical applications, and representative α+β type titanium, Ti-6Al-4V ELI, for biomedical applications cast by dental precision casting using commercial alumina, magnesia and modified magnesia based investment materials. Then the effect of specimen diameter on tensile properties of both cast alloys was also investigated.<BR>Elongation of cast tensile specimens of both alloys slightly increases and strength of cast tensile specimen of Ti-6Al-4V ELI increases with reducing casting defects. Hardness of surface reaction layer decreases, and hardness of matrix decreases by about 50 Hv due to increasing cooling rate by reducing the specimen diameter from 3 to 2 mm in both alloys. The microstructures of both cast alloys refines with reducing specimen diameters, and the hardness of surface reaction layers and matrix of both alloys decreases. Therefore, increasing strength of cast Ti-6Al-4V ELI with reducing specimen diameter is attributed to reducing casting defects.

収録刊行物

  • 鉄と鋼

    鉄と鋼 90 (10), 827-834, 2004

    一般社団法人 日本鉄鋼協会

参考文献 (14)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ