Experimental studies on the correction factor for the external conversion method of gamma ray measurements

Search this Article

Author(s)

Abstract

The correction factor in the external conversion method due to anisotropy of photoelectrons was calculated using two kinds of angular distribution functions. The calculated correction factors were compared with each other and tested by measurement of internal and external conversion lines of Au^<198> and Cs^<l37>. It was found that the correction factors calculated using angular distribution functions given by Hultberg are correct, and that the effect of the Z-dependence of angular distribution functions on the correction factor is negligible for Z=82 and 92

Journal

  • Journal of the Physical Society of Japan

    Journal of the Physical Society of Japan 21(11), 2097-2102, 1966-11

    The Physical Society of Japan (JPS)

Codes

  • NII Article ID (NAID)
    110001952356
  • NII NACSIS-CAT ID (NCID)
    AA00704814
  • Text Lang
    ENG
  • ISSN
    00319015
  • NDL Article ID
    8500896
  • NDL Source Classification
    ZM35(科学技術--物理学)
  • NDL Call No.
    Z53-A404
  • Data Source
    NDL  NII-ELS 