書誌事項
- タイトル別名
-
- On the Accuracy and the Method of Data Treatment for X-Ray Stress Measurement of 18Cr-8Ni Austenitic Stainless Steel
- 18Cr 8Ni オーステナイトケイ ステンレス コウXセン オウリョク ソク
この論文をさがす
抄録
The X-ray stress measurements were carried out on 18Cr-8Ni austenitic stainless steel specimens with different half-value breadths by the fixed ψ0 and ψ0 oscillation methods with CrKβ γ(311) diffraction. The peak position of the diffraction profile was determined by several methods, such as the half-value breadth method, the parabola fitting method and the center of gravity method by a computer and the accuracy of stress measurement was examined. The results obtained were as follows:<br>(1) It is not desirable to determine the peak position of diffraction profile by the center of gravity method, from a viewpoint of the accuracy of the computation.<br>(2) When the data of X-ray stress measurements obtained by the fixed ψ0 and ψ0 oscillation method were treated by using the half-value breadth or the parabola fitting method with corrections for background and an absorption factor, the error was as small as that of the graphic half-value breadth method.<br>(3) The corrected value of the absorption factor obtained from the normal distribution curves instead of the diffraction profies was not necessarily the same with the experimental value.
収録刊行物
-
- 材料
-
材料 29 (320), 428-433, 1980
公益社団法人 日本材料学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282680369010560
-
- NII論文ID
- 110002298226
-
- NII書誌ID
- AN00096175
-
- ISSN
- 18807488
- 05145163
-
- NDL書誌ID
- 2180257
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可