The advanced co-generation system (ACGS) was built at Waseda University in 1999. The ACGS consists of a gas turbine, a steam turbine, an ammonia-water mixture turbine, an ammonia absorption refrigerator and an ice storage system. Three turbine systems have a cascade relation upon the utilization of energy. In addition, the ammonia-water mixture turbine and the ammonia absorption refrigerator are located in the bottoming stage of the ACGS to utilize the lower temperature steam. In this paper, a mathematical model of the bottoming stage of the ACGS is established according to the experimental date. And the batter mechanism of ice storage system is discussed from the view of optimal planning with component-lag.