3-ヒドロキシ-7-メトキシフラボンとの錯形成速度の差を用いるアンチモン(III)及びアンチモン(V)の定量

DOI 機関リポジトリ NDLデジタルコレクション HANDLE Web Site ほか1件をすべて表示 一部だけ表示 被引用文献10件

書誌事項

タイトル別名
  • Kinetic determination of antimony (III) and antimony (V) based on the difference in their rates of complexation with 3-hydroxy-7-methoxyflavone.
  • 3‐ヒドロキシ‐7‐メトキシフラボンとの錯形成速度の差を用いるアンチモン(III)及びアンチモン(V)の定量
  • 3 ヒドロキシ 7 メトキシフラボン ト ノ サク ケイセイ ソクド ノ サ

この論文をさがす

抄録

Complexation reactions of antimony(III) and antimony(V) with 3-hydroxy-7-methoxyflavone have been studied fluorometrically. The concentration of sulfuric acid giving the complex with maximum fluorescence intensity was 34 M for antimony(III) and around 0.01 M for antimony(V). The time necessary to complete the reaction at the respective concentrations of sulfuric acid was within the dead time of mixing of reaction solutions (about four seconds) for antimony(III) and about thirty minutes for antimony(V). Based on these differences in fluorescence characteristics of the complexes and reactivities of the metal ions, antimony(III) up to 1×10-6 M was selectively determined in 3 M sulfuric acid by the linear extrapolation method with a detection limit of 7× 10-9 M and antimony(V) up to 1×10-6 M was selectively determined in 0.03 M sulfuric acid by the fixed time method with a detection limit of 2×10-8 M. Simultaneous determination of antimony(III) and antimony(V) was also possible for samples containing 1×10-6 M total antimony in 1 M sulfuric acid.

収録刊行物

  • 分析化学

    分析化学 40 (9), 455-460, 1991

    公益社団法人 日本分析化学会

被引用文献 (10)*注記

もっと見る