Application of the OS-EM Method to the <123>^I-IMP ARG Method : Comparison between FBP and OS-EM Methods
-
- SASAKI KAZUKO
- Department of Radiology and Nuclear Medicine, Akita Prefectural Rehabilitation Center for the Physically Disabled & Medical Center for Mental Health
-
- SATOU AYUKO
- Department of Radiology and Nuclear Medicine, Akita Prefectural Rehabilitation Center for the Physically Disabled & Medical Center for Mental Health
-
- OOMURA TOMOMI
- Department of Radiology and Nuclear Medicine, Akita Prefectural Rehabilitation Center for the Physically Disabled & Medical Center for Mental Health
-
- ONO MADOKA
- Department of Radiology and Nuclear Medicine, Akita Prefectural Rehabilitation Center for the Physically Disabled & Medical Center for Mental Health
-
- HACHIYA TAKENORI
- Department of Radiology and Nuclear Medicine, Akita Prefectural Rehabilitation Center for the Physically Disabled & Medical Center for Mental Health
Bibliographic Information
- Other Title
-
- OS-EM法の<sup>123</sup>I-IMP ARG法への適用の試み : FBP法との比較
Search this article
Abstract
We investigated application of the OS-EM method to the <123>^I-IMP ARG method to measure regional cerebral blood flow (rCBF). First, scan time and subsets were fixed at 20 min and 16, respectively, and the influence of iteration on the CCF and quantitative rCBF values obtained by the ARG method was investigated when the iteration number was set at 2, 4, 8, 16, 32, and 90. Next, with the number of iterations set at 4, we compared the scanning times of OS-EM and FBP. We determined that the CCF values remained at the same level irrespective of iteration number. Quantitative rCBF values had no association with iteration number, either. Using the quantitative rCBF values obtained by 20-min. scanning with FBP as a standard, the time period for collecting SPECT data was 10 min, without sacrificing image quality or quantification. Quantitative rCBF obtained by OS-EM was estimated to be higher than that by FBP.
Journal
-
- Japanese Journal of Radiological Technology
-
Japanese Journal of Radiological Technology 60 (5), 734-739, 2004
Japanese Society of Radiological Technology
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282681365577216
-
- NII Article ID
- 110003434612
-
- NII Book ID
- AN00197784
-
- ISSN
- 18814883
- 03694305
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed