書誌事項
- タイトル別名
-
- A Fixed Partial Denture Supported by Titanium-Nickel Shape Memory Alloy. Pin Bridge System. Part 2. Retentive Force of Pins.
- Pin Brid ge C19System-Part 2. Retentive Force of Pins
- その2. ピンの維持力
この論文をさがす
抄録
As described before, we developed a fixed partial denture supported by several pins attached to the proximal surfaces of the abutment teeth adjacent to the missing site. In this study, further investigation was carried out concerning 1) the effects of the pretreatment of adherent surfacesof Ti alloy pin, Ti-Ni shape memory alloy pin, and prepared retention hole on the tensile and shearing forces; 2) the effect of the morphological variance of the retentive region of the pin on the tensile and shearing forces; 3) the effect of the luting cement difference on the tensile force. The pin (1.8 mm length) with a doughnut-like structure was luted to the retention hole prepared in extracted teeth with an adhesive resin cement (Panavia 21, Kuraray) and a glassionomer cement (HY-BOND Glassionomer Cement, Shofu) for various adherent surface treatments.<BR>Overall data showed that the combination of the Ti-Ni shape memory alloy pin and the adhesive resin cement improved the retentive force of the pin.
収録刊行物
-
- 日本補綴歯科学会雑誌
-
日本補綴歯科学会雑誌 40 (6), 1050-1056, 1996
社団法人 日本補綴歯科学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390001204409385856
-
- NII論文ID
- 110003856647
-
- NII書誌ID
- AN00197911
-
- ISSN
- 1883177X
- 03895386
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可