書誌事項
- タイトル別名
-
- Relation between solution-pump error and transitional change of state at absorber in ammonia -absorption refrigerator.
抄録
This paper reports about the mechanism of pump error at starting-up of ammonia-absorption refrigerator, and the countermeasure for it. First, the authors analyzed relations between the pump error and the transitional change of state at the absorber. Then, the starting-up experiments to evaluate the countermeasure for the pump error are carried out. Consequently, there is the optimum ammonia-water solution flow rate through the spray nozzle of the absorber. And no pump error occurs at the solution flow rate.
収録刊行物
-
- 年次大会講演論文集
-
年次大会講演論文集 2004.3 (0), 23-24, 2004
一般社団法人 日本機械学会