都市表面における対流物質伝達率に関する風洞実験(続報) : 都市域における建物外表面対流熱伝達率に関する実験的研究(その3)

書誌事項

タイトル別名
  • SEQUEL TO THE WIND TUNNEL TEST ON CONVECTIVE MASS TRANSFER COEFFICIENT AT URBAN SURFACE : Study on convective heat transfer coefficient at outside building wall in an urban area Part 3
  • トシ ヒョウメン ニ オケル タイリュウ ブッシツ デンタツリツ ニ カンスル フウドウ ジッケン ゾクホウ トシイキ ニ オケル タテモノ ガイヒョウメン タイリュウ ネツ デンタツリツ ニ カンスル ジッケンテキ ケンキュウ ソノ 3

この論文をさがす

抄録

A major problem in urban climate modeling is determining how the heat fluxes from various canyon surfaces are affected by canyon flow. To address this problem, we developed a water evaporation method involving filter paper to study the distribution of the convective transfer velocity in urban street canyons. For 3D cubic arrays, the relation to canyon aspect ratio was largely different from that of 2D canyon. And, as a case study, the variation of wind direction was investigated for some city-like setting. The area-averaged transfer velocity was insensitive to wind direction but its local deviation was significant. In addition, we measured the transfer velocity for a clustered block array surrounded by relatively wide streets. The effect of spatial heterogeneity on the transfer velocity was significant. Moreover, for a fixed total building volume, the transfer velocity was considerably larger when the building height varied, than when it was uniform. Therefore, the water evaporation method with filter paper is expected to be useful for studying the transfer velocity and ventilation rates in urban areas with various canyon shapes.

収録刊行物

被引用文献 (2)*注記

もっと見る

参考文献 (15)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

問題の指摘