書誌事項
- タイトル別名
-
- Study on Radial Pressure Measuring Method of Gland Packing
- グランドパッキン ソクアツ ソクテイホウ ノ ケンキュウ
この論文をさがす
抄録
For the users of automatic control valves, leakage of the fluid from the gland packing portion has been a problem as main cause of failure. In this research, the measuring method of the radial pressure of the gland packing, which is directly related to the sealing characteristics, is proposed. The semiconductor pressure transducer is attached to the bonnet, and through the grease filled in the hole in the bonnet, the radial pressure was directly measured. First, the validity of the proposed method was confirmed by comparison of the result to the pressure value expected from the strain of the bonnet. Next, this measuring method was applied to the model system. The radial pressure distribution of the piled packing and its dynamic behavior under conditions the stem was driven was successfully observed. Consequently, the method was shown to be useful to observe the radial pressure distribution, especially in dynamic conditions.
収録刊行物
-
- 精密工学会誌論文集
-
精密工学会誌論文集 72 (10), 1301-1306, 2006
公益社団法人 精密工学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282680258769408
-
- NII論文ID
- 110004810087
-
- NII書誌ID
- AA11966630
-
- ISSN
- 18818722
- 13488716
- 13488724
-
- NDL書誌ID
- 8536944
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可