床スラブに接着したシアキープレートによる鋼構造用耐震補強ブレース接合部の耐力評価  [in Japanese] ESTIMATION OF STRENGTH OF SEISMIC RETROFITTING BRACE JOINT USING SHEAR-KEY PLATE ADHERED TO CONCRETE SLAB FOR STEEL STRUCTURE  [in Japanese]

Access this Article

Search this Article

Author(s)

Abstract

Incorporating additional braces is representative method for seismic retrofit for steel structure. In the case of installing the braces, the welding of steel and chipping of floor concrete cause noise and vibration. In order to solve this problem, the previous paper proposed a new method using a shear-key plate adheared to concrete slab with epoxy resin. The failure of this method is brittle, but on the assumption that a buckling restrained brace with low yield steel of its core is applied, this joint is useful for a practical structure. This paper reports the strength of the adheared portion.

Journal

  • Journal of Structural and Construction Engineering (Transactions of AIJ)

    Journal of Structural and Construction Engineering (Transactions of AIJ) 71(610), 177-184, 2006