関西地域の住宅における冬期の実態調査による中立温度・許容範囲の算出 CALCULATION OF NEUTRAL TEMPERATURE AND ACCEPTABLE RANGE BY THE FIELD STUDY OF HOUSES IN KANSAI AREA, JAPAN, IN WINTER

この論文にアクセスする

この論文をさがす

著者

抄録

Thermal environment of the houses in Kansai area, Japan, was investigated in winter. This paper discussed indoor climate and thermal comfort. The main results are as follows; l) the ratio of occupants who did warming action such as to use kotatsu or electric carpet, as well as using heating such as air-conditioning and heaters was higher than that of occupants who used heating only, 2) the neutral temperature was 9.9℃(ET*) when occupants didn't do warming action, 3) the neutral temperature was 9.9℃(Tg), 10.9℃(OT), 10.9℃(ET*) when occupants wore much clothing, 4) more than 90% of occupants responded "acceptable", despite 70% of the temperature data varying from ASHRAE Standard55.

収録刊行物

  • 日本建築学会環境系論文集

    日本建築学会環境系論文集 72(614), 71-77, 2007

    日本建築学会

参考文献:  40件中 1-40件 を表示

被引用文献:  3件中 1-3件 を表示

各種コード

  • NII論文ID(NAID)
    110006242045
  • NII書誌ID(NCID)
    AA11830377
  • 本文言語コード
    JPN
  • 資料種別
    ART
  • ISSN
    1348-0685
  • NDL 記事登録ID
    8776133
  • NDL 雑誌分類
    ZN1(科学技術--建設工学・建設業)
  • NDL 請求記号
    Z74-D484
  • データ提供元
    CJP書誌  CJP引用  NDL  NII-ELS  J-STAGE 
ページトップへ