Buildings composed of coupled shear walls with damper, CFT column, and flat plate slabs is one of the type of buildings that can be reused after severe earthquakes with low repair cost. To evaluate the vertical load resistance capacity of the newly designed CFT column-flat plate connection, two series of experimental studies for element specimens were carried out. Total of thirty-four specimens are tested and strength capacities of the results were examined using vertical load resistance macro models and showed good agreement. At design, the vertical strength can be evaluated by the ACI and AIJ standards in the safe side.