Development of the Certified Reference Materials, Plastics (JSAC 0631, JSAC 0632) for Determination of Hazardous Metals by X-Ray Fluorescence Analysis
-
- NAKANO Kazuhiko
- The Japan Society for Analytical Chemistry
-
- NAKAMURA Toshihiro
- The Japan Society for Analytical Chemistry
-
- NAKAI Izumi
- The Japan Society for Analytical Chemistry
-
- KAWASE Akira
- The Japan Society for Analytical Chemistry
-
- IMAI Makoto
- The Japan Society for Analytical Chemistry
-
- HASEGAWA Mikio
- The Japan Society for Analytical Chemistry
-
- ISHIBASHI Yo-ichi
- The Japan Society for Analytical Chemistry
-
- INAMOTO Isamu
- The Japan Society for Analytical Chemistry
-
- SUDOU Kazuhuyu
- The Japan Society for Analytical Chemistry
-
- KOZAKI Masaru
- The Japan Society for Analytical Chemistry
-
- TURUTA Akira
- The Japan Society for Analytical Chemistry
-
- BANDO Atsushi
- The Japan Society for Analytical Chemistry
-
- ONO Akihiro
- The Japan Society for Analytical Chemistry
-
- KAKITA Kazutoshi
- The Japan Society for Analytical Chemistry
-
- TAKIMOTO Kenichi
- The Japan Society for Analytical Chemistry
-
- SAKATA Mamoru
- The Japan Society for Analytical Chemistry
Bibliographic Information
- Other Title
-
- 有害金属成分蛍光X線分析用プラスチック認証標準物質JSAC 0631, 0632の開発
- テクノレポート 有害金属成分蛍光X線分析用プラスチック認証標準物質JSAC 0631,0632の開発
- テクノ レポート ユウガイ キンゾク セイブン ケイコウ Xセン ブンセキヨウ プラスチック ニンショウ ヒョウジュン ブッシツ JSAC 0631 0632 ノ カイハツ
Search this article
Abstract
The Japan Society for Analytical Chemistry has developed plastic certified reference materials (CRMs) for the X-ray fluorescent analysis of four hazardous elements: Pb, Cd Cr and Hg in plastics. Disk samples were prepared by filling Al-cylindrical molds with the raw material liquid of polyester resin mixed with hardener and organometallic compounds. Thus 360 candidate reference materials of JSAC 0631 and 0632 were obtained. Both surfaces on prepared disks obtained after 12 h of hardening at room temperature were ground and polished by a milling machine at 4.00±0.05 mm thick. The homogeneity of the prepared disks was shown excellently. An interlaboratory comparison study was performed by 24 laboratory's participants. In a statistical evaluation for the interlaboratory study, z-scores in the "robust method" were applied in order to reject outlier. The certified uncertainties for prepared CRMs were determined at in the confidence levels of 95%.<br>
Journal
-
- BUNSEKI KAGAKU
-
BUNSEKI KAGAKU 56 (5), 363-370, 2007
The Japan Society for Analytical Chemistry
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001204353952768
-
- NII Article ID
- 110006273878
-
- NII Book ID
- AN00222633
-
- COI
- 1:CAS:528:DC%2BD2sXlsFOksL8%3D
-
- NDL BIB ID
- 8823525
-
- ISSN
- 05251931
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- NDL-Digital
- CiNii Articles
- KAKEN
-
- Abstract License Flag
- Disallowed