High-performance liquid chromatographic measurement of nicotinamide N-oxide in urine after extracting with chloroform.
-
- SHIBATA Katsumi
- Department of Food Science and Nutrition, Teikoku Women's University
この論文をさがす
抄録
The measurement of nicotinamide N-oxide by high-performance liquid chromatography is described. The method used a Chemcosorb 5-ODS-H (150 × 4.5 mm i.d., particle size 5 μm) column eluted with 10 mM potassium dihydrogenphosphate (pH was adjusted to 3.0 by adding concentrated phosphoric acid) containing 0.1 g/l of sodium 1-octanesulfonate-methanol (100:4, v/v) at a flow-rate of 1.0ml/min. The UV detector was set at 260nm. The detection limit for nicotinamide N-oxide was 2pmol (276 pg) at a signal-to-noise ratio of 5:1. Under these conditions, nicotinamide N-oxide was eluted at about 3.2 min. This technique was used to analyze rat urine following effective clean-up steps with chloroform, the total analysis time being about 13 min.
収録刊行物
-
- Agricultural and Biological Chemistry
-
Agricultural and Biological Chemistry 53 (5), 1329-1331, 1989
公益社団法人 日本農芸化学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282681442095872
-
- NII論文ID
- 110006324319
-
- NII書誌ID
- AA00515312
-
- COI
- 1:CAS:528:DyaL1MXktlKjt7Y%3D
-
- ISSN
- 18811280
- 00021369
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可