標準熱回収率による地下熱利用システムの評価方法および住宅への導入効果に関する研究  [in Japanese] Evaluation of Underground Thermal Energy Utilization by using Standard Thermal Recovery Ratio and its Application to a Residential Heating System  [in Japanese]

Access this Article

Search this Article

Author(s)

    • 濱田 靖弘 HAMADA Yasuhiro
    • 北海道大学大学院工学研究科都市環境工学専攻 Division of Urban and Environmental Engineering, Graduate School of Engineering, Hokkaido University
    • 中村 真人 NAKAMURA Makoto
    • 北海道大学大学院工学研究科都市環境工学専攻 Division of Urban and Environmental Engineering, Graduate School of Engineering, Hokkaido University
    • 落藤 澄 OCHIFUJI Kiyoshi
    • 北海道大学大学院工学研究科都市環境工学専攻 Division of Urban and Environmental Engineering, Graduate School of Engineering, Hokkaido University
    • 横山 真太郎 YOKOYAMA Shintaro
    • 北海道大学大学院工学研究科都市環境工学専攻 Division of Urban and Environmental Engineering, Graduate School of Engineering, Hokkaido University
    • 長野 克則 NAGANO Katsunori
    • 北海道大学大学院工学研究科都市環境工学専攻 Division of Urban and Environmental Engineering, Graduate School of Engineering, Hokkaido University
    • 永坂 茂之 NAGASAKA Shigeyuki
    • 北海道大学大学院工学研究科都市環境工学専攻 Division of Urban and Environmental Engineering, Graduate School of Engineering, Hokkaido University

Abstract

本論文では,地下熱利用による冷暖房の可能性を検討することを目的として,年間サイクルを考慮した垂直埋設管方式の採熱と放熱の基本的な特性についての解析と実験を行った.まず,標準熱回収率を用いた解析により,単管方式は熱源型,複数管方式は蓄熱型による利用が有効であることを示し,後者においては最大採熱量が得られる埋設間隔が存在することを示した.次に,土壌熱源ヒートポンプの実験と解析より,土壌は安定した熱源であり,長期的な利用が可能であることを明らかにした.さらに,高断熱住宅を対象として,空気熱源ヒートポンプとの比較を行い,土壌熱源ヒートポンプが省エネルギー性,環境性に優れた暖房方式であることを示した.

This study describes analyses and experiments on fundamental thermal characteristics of vertical heat exchanger's annual energy cycle in order to specify the availability of underground thermal energy utilization for heating and cooling. First of all, it was shown that a single bore-field was more effectively utilized as a heat source and a multiple bore-field as a storage medium. This was determined by analyses on standard thermal recovery ratio. A multiple bore-field has an optimum bore-spacing which maximizes the amount of heat extraction. Next, we evaluated the performance of a ground source heat pump system by experiments and analyses. We found that underground thermal energy could be utilized over a long period of time. We also compared the ground source heat pump and an air source heat pump for heating of a super insulated house. The ground source heat pump is a superior heating system for energy conservation and environmental protection.

Journal

  • Transactions of the Society of Heating,Air-conditioning and Sanitary Engineers of Japan

    Transactions of the Society of Heating,Air-conditioning and Sanitary Engineers of Japan 23(71), 53-62, 1998

    The Society of Heating, Air-Conditioning & Sanitary Engineers of Japan

References:  31

Cited by:  26

Codes

  • NII Article ID (NAID)
    110007996294
  • NII NACSIS-CAT ID (NCID)
    AN00065706
  • Text Lang
    JPN
  • Article Type
    Journal Article
  • ISSN
    0385-275X
  • NDL Article ID
    4587557
  • NDL Source Classification
    ZN5(科学技術--建設工学・建設業--都市工学・衛生工学)
  • NDL Call No.
    Z16-955
  • Data Source
    CJP  CJPref  NDL  NII-ELS  J-STAGE 