AM06-17-002 ADCP移動観測による流量計測の精度検証(河川・湖沼・沿岸域の環境流体(1),一般講演)

書誌事項

タイトル別名
  • AM06-17-002 Verification for accuracy of river-discharge evaluated with a moving ADCP

この論文をさがす

抄録

Since an acoustic Doppler current profiler (ADCP) can measure both vertical velocity profile and water depth, it has high potential for measuring river discharge. However there are no well-established ways for river-discharge measurements with the ADCP. In the present study, we try to examine the accuracy and fundamental performance of the river-discharge measurements by using a moving ADCP. The field tests with the moving ADCP were conducted in the Edo River under low- and flood-flow conditions. The observed results indicate that the moving ADCP has high accuracy for the river-discharge evaluation. It should be also noted that the discharge evaluation are significantly influenced with the treatment of moving bottom velocity which exceeds 0.2m/s in flood flow conditions.