Study on Sensitive and Dynamic Seismic Diagnosis for 2-storied Wooden Houses Using Horizontal Vibration Generator

  • Imaoka Katsuya
    Department of Architecture, Toyota National College of Technology
  • Iwasaki Masashi
    Civil Engineering and Architecture Course, Toyota National College of Technology
  • Umemura Kazuki
    Department of Architecture, Toyota National College of Technology
  • Kano Ryota
    Department of Architecture, Toyota National College of Technology

Bibliographic Information

Other Title
  • 水平起振器を用いた木造2階建住宅の体感型耐震診断法に関する研究
  • スイヘイキシンキ オ モチイタ モクゾウ 2カイダテ ジュウタク ノ タイカンガタ タイシン シンダンホウ ニ カンスル ケンキュウ

Search this article

Abstract

In order to evaluate the seismic performance of 2-storied wooden houses which were built before 1981, the sensitive and dynamic diagnosis using horizontal vibration generator have been carried out to 80 houses in Toyota city.From the investigation, the natural frequency of the houses becomes higher when the weight of the roof is lighter and the seismic capacity grade ratio is bigger in case of full 2-storied type. When the houses have enough measurement space at the second floor, the torsional amplitude ratios from this method properly correspond to the eccentricity of the houses.