Most solar photovoltaic cells are incorporated in building only for electricity supply. As the interior surface of the photovoltaic (PV) cells is increased to about 60℃, the air nearby is heated. If the PV cells are used as roof materials in the atrium space, the stack effect can also be expected, which will assisted the natural ventilation in the building. Here a roof system integrated with amorphous silicon PV cells is proposed in a model house, and the stack effect is measured by model experiment, as well as the air temperature stratification, natural ventilation volume.