G-10 オアシス21の環境特性に関する研究 : (第3報)ヒートフラックスと都市への影響 G-10 A Study on Characteristics of Environment in Oasis 21 : Part 3 Heat Flux and Effects to the Urban Environment

この論文にアクセスする

著者

抄録

We measured the sensible and latent heat flux on the glass roof with water pond and the grass yard at the Oasis2l. The sensible heat flux on the water pond was 1/10 times larger than on the grass. The Bowen ratio is 2.0 on the grass and 0.2 on the water pond. And we suggested a possibility that the measurement of sensible heat flux above the void area using Scintillometer. The heat flux and temperatures around grass surface was calculated by numerical models. In as a consequence, the flux value was calculated almost properly. The thermal impacts of Oasis2l that the influence to the around thermal environment and radiant environment and so on are confirmed.

収録刊行物

  • 空気調和・衛生工学会大会 学術講演論文集

    空気調和・衛生工学会大会 学術講演論文集 2004.1(0), 517-520, 2004

    公益社団法人 空気調和・衛生工学会