H-16 光透過型太陽電池パネルを住宅に設置した場合の省エネルギー性に関する研究
書誌事項
- タイトル別名
-
- H-16 Energy saving potential of semi-transparent photovoltaic In residential building application
抄録
A heat balance calculation model of semi-transparent photovoltaic (STPV) was constructed and incorporated into a building energy simulation model. Case study was carried out on a typical 4-person household residential building in Osaka, with two types of double glass STPV panels (20% and 50% solar transmission rate) located on the south-facing roof of the living zone. Reduction in heating energy was achieved but increment in cooling energy was observed, resulting in a net increase in total air conditioning energy consumption for both STPV panels. Daylighting energy saving was subtle in the current simulation condition the existing south glazing satisfied most of the illuminance demand.
収録刊行物
-
- 空気調和・衛生工学会大会 学術講演論文集
-
空気調和・衛生工学会大会 学術講演論文集 2006.1 (0), 703-706, 2006
公益社団法人 空気調和・衛生工学会