9-5-3 30kw級太陽電池-水電解・貯蔵・利用システムの特性 : (3) 水素貯蔵装置の特性(Session 9-5 水素製造・貯蔵・利用V)
書誌事項
- タイトル別名
-
- 9-5-3 Characteristics of 30kw Class PV-Electrolyzer-Hydrogen Storage-Utilization System : (3) Hydrogen Storage System
抄録
A bench-scale hydrogen production-storage-utilization system, "Pure Hydrogen Energy System", was constructed in Fukushima Renewable Energy Institute, AIST (FREA). This hydrogen energy system involves solar photovoltaic/thermal panels, water electrolyzers/fuel cells, metal hydride (MH) tanks, heat storage tank, cooling tower and their auxiliaries. In the present study, we focus on introduction of hydrogen storage system and presentation of hydrogen absorption of the MH tank with 70 kg LaNi_5. This MH tank was able to absorb hydrogen at the constant flow rate of 15-45 NL/min. Based on these results, we discuss the hydrogen absorption operation under the higher hydrogen flow rate of 83 NL/min (5 Nm^3/h), which is the maximum hydrogen flow rate of the water electrolyzers.
収録刊行物
-
- 日本エネルギー学会大会講演要旨集
-
日本エネルギー学会大会講演要旨集 24 (0), 326-327, 2015
一般社団法人 日本エネルギー学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282680789724544
-
- NII論文ID
- 110009996565
-
- ISSN
- 24238325
- 24238317
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可