Wall thickness measurement using resonant phenomena of circumferential Lamb waves generated by plural transducer elements located evenly on girth

IR

Search this article

Abstract

We present a novel method of measuring the pipe wall thickness using the resonance of the circumferential (C-) Lamb wave generated by a piezoelectric ring-shaped sensor (PS). The PS is a special device for an axially propagating torsional wave; however, the C-Lamb waves are generated simultaneously as spurious signals owing to the structure of the PS. Particularly under resonant conditions, the C-Lamb waves are dominantly generated, distorting the axially propagating wave. In this method, these troublesome spurious signals are used effectively for the measurement of the wall thickness under the PS location that is a dead zone of the PS itself. The method can compensate for its drawback, namely, the dead zone problem, without using additional instruments. In this study, the mechanisms of the generation and resonance of the C-Lamb waves were first explained. Secondly, the principle of the wall thickness estimation utilizing the resonance of the C-Lamb waves was proposed. Finally, experimental verifications were carried out. The estimated wall thicknesses agreed very well (maximum 1.5% error) with those measured by a micrometer caliper under suitable resonant conditions.

Journal

Related Projects

See more

Details 詳細情報について

Report a problem

Back to top