Clinical evaluation of time-of-flight MR angiography with sparse undersampling and iterative reconstruction for cerebral aneurysms

  • Fushimi, Yasutaka
    Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine
  • Okada, Tomohisa
    Human Brain Research Center, Kyoto University Graduate School of Medicine
  • Kikuchi, Takayuki
    Department of Neurosurgery, Kyoto University Graduate School of Medicine
  • Yamamoto, Akira
    Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine
  • Okada, Tsutomu
    Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine
  • Yamamoto, Takayuki
    Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine
  • Schmidt, Michaela
    Diagnostic Imaging, Siemens Healthcare GmbH
  • Yoshida, Kazumichi
    Department of Neurosurgery, Kyoto University Graduate School of Medicine
  • Miyamoto, Susumu
    Department of Neurosurgery, Kyoto University Graduate School of Medicine
  • Togashi, Kaori
    Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine

Bibliographic Information

Other Title
  • Clinical evaluation of time‐of‐flight MR angiography with sparse undersampling and iterative reconstruction for cerebral aneurysms

Abstract

Compressed sensing (CS) MRI has just been introduced to research areas as an innovative approach to accelerate MRI. CS is expected to achieve higher k‐space undersampling by exploiting the underlying sparsity in an appropriate transform domain. MR angiography (MRA) provides high spatial resolution information on arteries; however, a relatively long acquisition time is necessary to cover a wide volume. Reduction of acquisition time by CS for time‐of‐flight (TOF) MR angiography (Sparse‐TOF) is beneficial in clinical examinations; therefore, the clinical validity of Sparse‐TOF needs to be investigated. The aim of this study was to compare the diagnostic capability of TOF MRA between parallel imaging (PI)‐TOF with an acceleration factor of 3 (annotated as 3×) and Sparse‐TOF (3× and 5×) in patients with cerebral aneurysms. PI‐TOF (3×) and Sparse‐TOF (3× and 5×) imaging were performed in 20 patients using a 3 T MRI system. Aneurysms in PI‐TOF (3×) and Sparse‐TOF (3× and 5×) were blindly rated as visible or scarcely visible by neuroradiologists. The neck, height and width of aneurysms were also measured. Twenty‐six aneurysms were visualized and rated as visible in PI‐TOF (3×) and Sparse‐TOF (3× and 5×), with excellent agreement between two raters. No significant differences were found in measured neck, height or width of aneurysms among them. Sparse‐TOF (3× and 5×) were acquired and reconstructed within 6 min, and cerebral aneurysms were visible in both of them with equivalent quality to PI‐TOF (3×). Sparse‐TOF (5×) is a good alternative to PI‐TOF (3×) to visualize cerebral aneurysms.

Journal

Citations (5)*help

See more

References(22)*help

See more

Related Projects

See more

Details 詳細情報について

Report a problem

Back to top