Conductive and viscous sub-layers on forced convection and mechanism of critical heat flux during flow boiling of subcooled water in a circular tube at high liquid Reynolds number

HANDLE オープンアクセス

この論文をさがす

抄録

The turbulent heat transfer, the subcooled boiling heat transfer and the steady state CHF for a Pt-circular test tube of a 3 mm inner diameter and a 100 mm heated length are measured with a wide range of inlet subcooling and flow velocity at high liquid Reynolds number, i.e. Re-d = 3.01x10(4) to 1.43x10(5). The inner surface temperature of the Pt-circular test tube calculated by the steady one-dimensional heat conduction equation is compared with the values derived from authors' turbulent heat transfer correlation and with the numerical solutions of the RANS equations (Reynolds Averaged Navier-Stokes Simulation) of k-ε turbulence model for the flow velocities ranging from 4 to 21 m/s. The thicknesses of conductive sub-layer from non-boiling regime to CHF are measured by numerically analyzing the heat transfers with conductive sub-layer on forced convection and with thinner one dissipated by the evaporation on nucleate boiling. The thicknesses of viscous sub-layer on forced convection are estimated from the thicknesses of the conductive sub-layer and Prandtl numbers of the surface temperature on the heated surface. Furthermore, the thicknesses of conductive sub-layer at the CHF point are extrapolated from the measured values at various flow velocities. The experimental values of the CHF are also compared with authors' widely and precisely predictable correlations of critical heat flux during flow boiling of subcooled water and the corresponding theoretical values of the liquid sub-layer dry-out models suggested by other researchers, respectively. The authors' correlations and other researchers' theoretical values can represent the subcooled boiling CHFs obtained in this study within the ranges of -13.27 to 6.76% difference and - 32.51 to 13.16% one, respectively. A suggestion based on the experimental data as to what the dominant mechanism is for critical heat flux during flow boiling of subcooled water on a vertical circular tube is confirmed again at high liquid Reynolds number. The transitions to film boiling at the subcooled water flow boiling on the Pt test tube of d = 3 mm and L = 100 mm would occur due to the liquid sub-layer dry-out model at the steady-state CHF as well as those on the Pt test tube of d = 3 mm and L = 66.5 mm, but not due to the heterogeneous spontaneous nucleation and the hydro-dynamic instability.

収録刊行物

詳細情報 詳細情報について

  • CRID
    1050856995323133312
  • NII論文ID
    120006599234
  • NII書誌ID
    AA1145499X
  • ISSN
    14321181
    09477411
  • HANDLE
    20.500.14094/90005760
  • 本文言語コード
    en
  • 資料種別
    journal article
  • データソース種別
    • IRDB
    • CiNii Articles

問題の指摘

ページトップへ