A thermocouple-based remote temperature controller of an electrically-floated sample for plasma CVD of nanocarbons with bias voltage
抄録
We report an accurate and easy-to operate instrument for the temperature control of an electrically floated sample using a thermocouple in direct contact with it. The signal was transmitted via 2.45 GHz WiFi. We measured and analyzed the discrepancy between the thermocouple and a radiation thermometer for the plasma CVD of carbon nanomaterials under sample bias. A successful protection method from abnormal discharge in the plasma is also provided. (C) 2017 Elsevier Ltd. All rights reserved.