Coherence between oscillations in the cardiorespiratory system and tissue oxygen index in muscle recovering from intensive exercise in humans

HANDLE オープンアクセス

書誌事項

タイトル別名
  • Coherence between cardiorespiratory system and TOI

この論文をさがす

抄録

It has been shown that the tissue oxygen index (TOI) measured by near-infrared spectroscopy oscillates at very low frequencies during recovery after exercise and that this oscillation is derived from interactions among biochemical substances involved in oxidative metabolism in skeletal muscle. As a further step, we examined whether TOI in muscle interacts through oscillation with factors related to oxygen in the cardiorespiratory system. For this examination, coherence and phase difference between the TOI in the vastus lateralis and heart rate (HR) and between TOI and arterial oxygen saturation (SpO2) were sequentially determined during recovery (2–60 min) after severe cycle exercise with a workload of 7.5% of body weight for 20 s. Significant coherence between TOI and HR was obtained in the very low-frequency band (approximate range: 0.002–0.03 Hz) and in the low-frequency band (approximate range: 0.06–0.12 Hz). The phase difference was negative in the low-frequency band and positive in the very low-frequency band. The coherence between TOI and SpO2 was significant in the very low-frequency band. The phase difference was negative. There were no sequential changes in these coherences and phase differences. The results suggest that TOI in skeletal muscle interrelates with factors related to the heart and lungs.

収録刊行物

詳細情報 詳細情報について

  • CRID
    1050845763995215360
  • NII論文ID
    120006732205
  • NII書誌ID
    AA10637167
  • HANDLE
    2115/75786
  • ISSN
    2498602X
  • 本文言語コード
    en
  • 資料種別
    journal article
  • データソース種別
    • IRDB
    • CiNii Articles

問題の指摘

ページトップへ