触媒反応を利用した水素-空気超音速混合の評価

IR

Bibliographic Information

Other Title
  • Evaluation of hydrogen-air supersonic mixing condition using catalytic reaction

Search this article

Abstract

An experiment was carried out to confirm the validity of time series evaluation of supersonic mixing condition by using catalytic reaction on a platinum wire. Gaseous hydrogen was injected into supersonic free-stream (M1 = 1.81) from injector. Time series condition of supersonic mixing was evaluated by using W-type probe which has a platinum wire and reference wire (nickel wire). The evaluation was done by simultaneously measuring each electric power supplied by each electric circuit which kept the temperature of wire constant. Specifically supplied electric power to Pt wire depended on catalytic heat release rate (giving hydrogen concentration) and flow convection. Meanwhile that to Ni wire depended on flow convection. The result showed that correlation coefficient between these electric powers increased when mixing developed. Investigations were also conducted for helium, air and no secondary injectant cases to compare with the hydrogen injectant case. The results indicated that it was possible to measure the time-series behavior of air-hydrogen supersonic mixing layer or coherent motion of turbulence by using this evaluation.

資料番号: AA0063156003

レポート番号: JAXA-SP-06-013

Journal

Related Projects

See more

Details 詳細情報について

Report a problem

Back to top