Development of a Field Test for Evaluating Aerobic Fitness

この論文をさがす

抄録

The purpose of this study was to investigate the reproducibility and utility of a standardised and externally paced field test (15-m Incremental Shuttle Walk and Run Test [15 mISWRT]) to assess aerobic fitness in middle-aged adults. 14 middle-aged participants performed the 15-m ISWRT 3 times within one week (Test 1, Test 2, Test 3). Reproducibility of the 15-m ISWRT was tested by comparing 15-m ISWRT performance (distance completed), HRmax, and V˙O2max for each test. The utility of the 15-m ISWRT for evaluating V˙O2max over a wide range in middle-aged adults was tested by comparing the range of V˙O2max obtained from the portable expired gas analyzer with the V˙O2max reference values and ranges for health promotion published by Japan's Ministry of Health, Labour and Welfare. A multiple comparison of distance completed in the 15-m ISWRT Test 1, Test 2, and Test 3 found no significant difference between Test 2 and Test 3. The ICC was 0.99 for Test 2 vs. Test 3. V˙O2max measured from the 15-m ISWRT in Test 3 had a minimum value of 22.8 ml/kg/min and a maximum value of 38.7 ml/kg/min. In conclusion, the 15-m ISWRT is reliable and useful for evaluating V˙O2max in middle-aged adults.

International Journal of Sports Medicine, 33(05), pp.346-350; 2012

収録刊行物

詳細情報 詳細情報について

問題の指摘