Development of a Signal-Averaged Vector-Projected 187-Channel High-Resolution Electrocardiogram for the Evaluation of the Spatial Location of High-Frequency Potentials and Abnormal Ventricular Repolarization
-
- Nakai Kenji
- Department of Laboratory Medicine, Iwate Medical University
-
- Tsuboi Junichi
- Department of Cardiovascular Surgery, Iwate Medical University
-
- Okabayashi Hitoshi
- Department of Cardiovascular Surgery, Iwate Medical University
-
- Fukushima Akimune
- Department of Obstetrics and Gynecology, Iwate Medical University
-
- Itoh Manabu
- ICS, Co., Ltd. Iwate
-
- Kawata Hiroshi
- Division of Medical Engineering and Clinical Investigation Institute of Development, Aging and Cancer, Tohoku University
-
- Miyake Fumihiko
- Department of Cardiology, St. Marianna University School of Medicine
-
- Kasanuki Hiroshi
- Department of Cardiology, Tokyo Women's Medical College
この論文をさがす
抄録
Noninvasive risk stratification is important for screening for lethal arrhythmia.<br> We developed a 187-channel signal-averaged vector-projected high-resolution electrocardiograph (187-ch SAVP-ECG) for detecting abnormalities in the spatial location of ventricular high-frequency late potentials (HFLPs) and ventricular repolarization. <br> The subjects consisted of 30 normal controls (CONTROL) and 13 patients with HFLPs (6 with myocardial infarction [MI], 6 with cardiomyopathy, and 1 with Brugada syndrome). The modified X, Y, Z-lead ECG and the synthesized signals from vector-projected 187-channel ECGs were amplified and passed through a digital filter. We calculated the integration of the HFLPs area between QRSend and 30 ms before QRSend. The integrated HFLPs map was superimposed on the corrected recovery time (RTc) and Tpeak-end dispersion maps composed by 187-ch SAVP-ECG. All patients received an examination by 64-channel magnetocardiography (64-ch MCG) on the same day. <br> The spatial distribution of HFLPs by the 187-ch SAVP-ECG map was in agreement with the location of increased RT dispersion in MI. The spatial distribution of HFLPs in DCM demonstrated a wide variety of patterns. Interestingly, the spatial distribution of HFLPs in cases with ARVC was located at around a right ventricular outflow region. The spatial distribution of HFLPs by 187-ch SAVP-ECG was in agreement with those determined by 64-ch MCG. <br> The 187-ch SAVP-ECG might be useful for evaluating the spatial distribution of nonuniform conduction and ventricular repolarization heterogeneity. <br>
収録刊行物
-
- International Heart Journal
-
International Heart Journal 48 (6), 701-713, 2007
一般社団法人 インターナショナル・ハート・ジャーナル刊行会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282680202584704
-
- NII論文ID
- 130000068982
-
- ISSN
- 13493299
- 13492365
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
- KAKEN
-
- 抄録ライセンスフラグ
- 使用不可