Development of Local Gas Temperature Measurement Technique inside a Combustion Chamber Using Two-Wire Thermocouple

Abstract

Thermocouples are widely used to measure the local gas temperature due to its accuracy and convenience. However, it is difficult to use thermocouples in a transient phenomenon such as reacting fields. In this study, the unsteady gas temperature inside a combustion chamber was measured by using an improved two-wire thermocouple technique. Based on previous two-wire methods, some modifications were examined. Firstly, numerical analysis of heat transfer between transient flow and thermocouple was performed to see what kind of modification was required. Secondly, a correction term was added to the basic equation, which was validated by experiments using a Rapid Compression and Expansion Machine. Finally, an improved two-wire thermocouple technique was evaluated by measuring the transient gas temperature inside a combustion chamber and compared to the estimated temperature using measured pressure data and assumptions of chemical equilibrium.

Journal

References(2)*help

See more

Details 詳細情報について

Report a problem

Back to top