インデューサのキャビテーション抑制法の開発 Suppression of Cavitation in Inducer by J-Groove

この論文にアクセスする

この論文をさがす

著者

抄録

Cavitation is the most serious problem in developing high-speed turbopump, and inducer is often used to avoid cavitation in main impeller. Thus, inducer is always operating in the worst cavitation condition. If it is possible to control and suppress cavitation in inducer by some new device, it might be possible to suppress cavitation occurring in any type of pumps. The purpose of present study is to develop a new effective method of controlling and suppressing cavitation in inducer using shallow grooves, which is named "J-Groove". J-Groove is installed on the casing wall near the blade tip to use the pressure difference between high pressure region and low pressure region of the inducer blade. The results show that proper combination of backward-swept inducer with J-Groove improves suction performance of turbopump remarkably in the range of partial flow rate as well as designed flow rate. The rotating backflow cavitation occurring in the range of low flow rate and the cavitation surge occurring in the vicinity of the best efficiency point can be almost suppressed by installing J-Groove.

収録刊行物

  • ターボ機械

    ターボ機械 33(10), 592-600, 2005

    日本工業出版

被引用文献:  1件中 1-1件 を表示

各種コード

  • NII論文ID(NAID)
    130000101174
  • NII書誌ID(NCID)
    AN00004836
  • 本文言語コード
    JPN
  • 資料種別
    journal article
  • ISSN
    0385-8839
  • NDL 記事登録ID
    7490993
  • NDL 雑誌分類
    ZN15(科学技術--機械工学・工業--流体機械)
  • NDL 請求記号
    Z16-978
  • データ提供元
    CJP引用  NDL  IR  J-STAGE 