A Large-Size Thermoacoustic Cooling System for a Practical Use (Study on Effect of Cross-Section Area of Tube on Energy Conversion into Sound from Heat)

Bibliographic Information

Other Title
  • 大型熱音響冷却システムの実用化に向けた検討(管の断面積が熱から音へのエネルギー変換に与える影響)

Abstract

Experimental investigation of the inner diameter in the thermoacoustic cooling system was carried out to confirm the effect for energy conversion efficiency. We carried out an experiment by using the thermoacoustic cooling system with 3 type inner diameters (24 mm, 42 mm, 100 mm). As results, acoustic power and a phase difference between sound pressure and particle velocity was varied. Moreover, it was confirmed that energy conversion efficiency in it changed with the variety of inner diameter. Energy conversion efficiency in it with inner diameter 100 mm was best of all. It is considered that a factor of improvement of energy conversion efficiency was change of phase difference between the sound pressure and the particle velocity.