書誌事項
- タイトル別名
-
- X-Ray fluorescence determination of iron and manganese in titanium
- チタン チュウ ノ テツ オヨビ マンガン ノ ケイコウ Xセン ブンセキ
この論文をさがす
抄録
Parallel examinations were done on the fluorescent X-ray spectrometric determination of iron and manganese in button ingots and forged blocks of titanium metal to know the effect of metallurgical history on X-ray measurement, the limit of detection and the range of inner- and inter-laboratory errors. By using the working curves established, the standard deviations of the analytical values were 0.003% and 0.0007%, respectively, for 0.0050.329% of iron and 0.0010.075% of manganese. The lower limits of detectionof iron and manganese were, respectively, 0.0026% and 0.0007%. The precision and accuracy of the result were higher than, or at least comparable to, those of the conventional chemical analysis. Discussions were given on the influence of Cr on X-ray intensities of MnKα line and also on the effect of metallurgical history of the specimens.
収録刊行物
-
- 分析化学
-
分析化学 20 (5), 601-606, 1971
公益社団法人 日本分析化学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390001204353686400
-
- NII論文ID
- 130000942483
-
- NII書誌ID
- AN00222633
-
- COI
- 1:CAS:528:DyaE3MXkslWjs7k%3D
-
- NDL書誌ID
- 8443966
-
- ISSN
- 05251931
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可