風の強弱が高所と地面付近との気温差および防霜ファンの効果に及ぼす影響 Influence of Wind Velocity Fluctuation on Air Temperature Difference between the Fan and Ground Levels and the Effect of Frost Protective Fan Operation

この論文にアクセスする

この論文をさがす

著者

    • 荒木 琢也 Araki Takuya
    • 独立行政法人農業・食品産業技術総合研究機構野菜茶業研究所 National Institute of Vegetable and Tea Science, National Agriculture and Food Research Organization
    • 松尾 喜義 Matsuo Kiyoshi
    • 独立行政法人農業・食品産業技術総合研究機構野菜茶業研究所 National Institute of Vegetable and Tea Science, National Agriculture and Food Research Organization
    • 深山 大介 [他] Miyama Daisuke
    • 独立行政法人農業・食品産業技術総合研究機構野菜茶業研究所 National Institute of Vegetable and Tea Science, National Agriculture and Food Research Organization
    • 角川 修 Sumikawa Osamu
    • 独立行政法人農業・食品産業技術総合研究機構野菜茶業研究所 National Institute of Vegetable and Tea Science, National Agriculture and Food Research Organization

抄録

防霜ファンの無駄な稼働を排した節電型の制御法の開発を目的として,茶園の風の強弱が高所と地面付近との気温差および防霜ファンの効果に及ぼす影響について調査した結果以下の点が明らかになった。<br>1)気象観測露場における観測から,地上6.5mの風速の増加に伴い,高所(4.8m)と低所(0.5m)の気温差は減少し,平均風速が3m/sを超える状況下では気温差が1℃以下だった。<br>2)風速2~3m/s程度以上の状況下では,防霜ファンの稼働に対応した樹冠面葉温の昇温効果が認められなかったが、風速がそれ以下の場合ははっきりと認められた。<br>以上の結果より,気温差や風速条件を防霜ファンの稼働制御に利用すれば,効果が期待できないような環境下での無駄な稼働をなくした節電型の制御が可能になると考えられた。

We invested the influence of wind velocity fluctuation on air temperature difference between the fan (4.8 m) and ground levels (0.5 m) and the effect of frost protective fan operation in order to develop a new method to reduce electricity consumption due to frost protective fan operation. The results of the investigations are summarized as follows:<br>(1) Air temperature difference between the fan (4.8 m) and ground levels (0.5 m) was decreased following an increase in wind velocity, and the difference was less than 1°C for a wind velocity more than 3.0 m/s at a height of 6.5 m.<br>(2) When the wind velocity was more than 2-3 m/s, there was hardly any increase in the temperature of the leaves. In contrast, when the wind velocity was less than 2-3 m/s, an increase in the temperature of the leaves was observed.<br>Based on these results, it is possible that when the wind velocity is greater than 2-3 m, it prevents thermal inversion. Therefore, there would be no warmer air for the frost protective fan to return to the tea plants and the air turbulence produced by the frost protective fan would not reach the plants under the windy condition.

収録刊行物

  • 茶業研究報告

    茶業研究報告 2008(106), 15-20, 2008

    日本茶業学会

各種コード

  • NII論文ID(NAID)
    130001275636
  • NII書誌ID(NCID)
    AN00143344
  • 本文言語コード
    JPN
  • 資料種別
    Journal Article
  • ISSN
    03666190
  • NDL 記事登録ID
    9796607
  • NDL 雑誌分類
    ZR7(科学技術--農林水産--農産)
  • NDL 請求記号
    Z18-1171
  • データ提供元
    NDL  IR  J-STAGE 
ページトップへ