魚肉すり身の示差走査熱測定
書誌事項
- タイトル別名
-
- Differential scanning calorimetry on fish meat paste.
- 魚肉すり身の示差走査熱測定〔英文〕
- ギョニク スリミ ノ シサ ソウサ ネツ ソクテイ エイブン
この論文をさがす
抄録
The thermal measurements using a differential scanning calorimeter was done with 10 kinds of fish meat, cuttlefish meat paste, and chicken meat paste. The total enthalpy change, ΔH, accompanied with the thermal gelation of meat pastes were estimated. Consequently, it was found that the easy-setting meat and the easy-disintegrating meat required a small quantity of heat in order to change the structure. The setting index (S) and the disintegration index (D) reported by Shimizu et al. depends on the ΔH-values as follows; ΔH=-0.0074S+1.047 ΔH=-0.0038D+0.783. Namely, the easy-setting property or the easy-disintegrating property corresponds to the fact that these meat pastes easily changed by a small quantity of heat. On the other hand, the correlation could not be found between ΔH and the gel-strength reported by Shimizu et al.
収録刊行物
-
- 日本水産学会誌
-
日本水産学会誌 57 (2), 337-340, 1991
公益社団法人 日本水産学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282681388647168
-
- NII論文ID
- 130001545251
-
- NII書誌ID
- AN00193422
-
- ISSN
- 1349998X
- 00215392
-
- NDL書誌ID
- 3706834
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- IRDB
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可