During the development of a synchroscan streak tube, a multipactor discharge which much increases background noise on the output screen has occurred. The relationships between the discharge and the operating conditions, the manufacturing process of the tube and the tube construction have been investigated. It has been found that the discharge can be prevented by adding a shield electrode near the deflection electrode. The developed tube is compact and easy to operate because it has low accelerating voltage of 5 kV and high deflection sensitivity of 50 mm/kVp-p. The spectral response covers over a range from 200 nm to 850 nm. It can be operated over wide sweeping frequencies ranging from 80 MHz to 160 MHz and the temporal resolution of _??_8ps has been obtained at 80 MHz. Moreover, it is very highly sensitive because a microchannel plate is incorporated and high speed gating is available by switching the applied voltage of the plate.