小型シンクロスキャンストリーク管の開発

DOI

書誌事項

タイトル別名
  • Development of a Compact Synchroscan Streak Tube

抄録

During the development of a synchroscan streak tube, a multipactor discharge which much increases background noise on the output screen has occurred. The relationships between the discharge and the operating conditions, the manufacturing process of the tube and the tube construction have been investigated. It has been found that the discharge can be prevented by adding a shield electrode near the deflection electrode. The developed tube is compact and easy to operate because it has low accelerating voltage of 5 kV and high deflection sensitivity of 50 mm/kVp-p. The spectral response covers over a range from 200 nm to 850 nm. It can be operated over wide sweeping frequencies ranging from 80 MHz to 160 MHz and the temporal resolution of _??_8ps has been obtained at 80 MHz. Moreover, it is very highly sensitive because a microchannel plate is incorporated and high speed gating is available by switching the applied voltage of the plate.

収録刊行物

  • 応用物理

    応用物理 57 (5), 774-783, 1988

    公益社団法人 応用物理学会

詳細情報 詳細情報について

  • CRID
    1390001204595783808
  • NII論文ID
    130003592241
  • DOI
    10.11470/oubutsu1932.57.774
  • ISSN
    21882290
    03698009
  • データソース種別
    • JaLC
    • CiNii Articles
  • 抄録ライセンスフラグ
    使用不可

問題の指摘

ページトップへ