蓄電池電壓の充電完了直後に於ける過渡現象に就て
書誌事項
- タイトル別名
-
- On the Transient Phenomena of Secondary Battery When the Charging Circuit is Opened
抄録
On opening the charging circuit, the high potential of storage battery on charge will recover its normal voltage within a short time. This is called the "Erholung des Accumulators" by Dolezalek and has been studied by former investigators, author of this paper furthermore investigated on this point and discussed the influence of Cadmium ion upon this phenomena.