同期整流器の時定数回路の改良

DOI

書誌事項

タイトル別名
  • Improvement on Time Constant Circuit of Synchronous Commutator System

抄録

Synchronous commutator system shows a sort of frequency selective character, which can be sharpened to any desired extent by increasing the time constant of indicator. If the time constant of the indicator is not large enough, the additional time constant circuit may be applied. However, the increased time constant requires longer measuring time, which is accompanied with various disadvantages. The author calculated the frequency selective characters obtained by multi-stage CR time constant networks whose time constant had been adjusted so as to have the transient time equal to that of the single stage which is usually used. The results show that the independed multistage CR circuits appeared in Figs. 9 and 10 have improved their characters. This fact was also confirmed by the simple experiment about the circuit (c) which is shown in Figs. 11, 12 and 13.

収録刊行物

  • 計測

    計測 7 (3), 140-145, 1957

    公益社団法人 計測自動制御学会

詳細情報 詳細情報について

  • CRID
    1390001205122143744
  • NII論文ID
    130003765193
  • DOI
    10.11499/sicejl1951.7.140
  • ISSN
    18838154
    04500024
  • 本文言語コード
    ja
  • データソース種別
    • JaLC
    • CiNii Articles
  • 抄録ライセンスフラグ
    使用不可

問題の指摘